0

Out of 0 Ratings

Owner's of the Friedrich Air Conditioner SQ10N10 gave it a score of 0 out of 5. Here's how the scores stacked up:
  • Reliability

    0 out of 5
  • Durability

    0 out of 5
  • Maintenance

    0 out of 5
  • Performance

    0 out of 5
  • Ease of Use

    0 out of 5
of 67
 
Undercharged Refrigerant Systems
An undercharged system will result in poor performance
(low pressures, etc.) in both the heating and cooling cycle.
Whenever you service a unit with an undercharge of
refrigerant, always suspect a leak. The leak must be
repaired before charging the unit.
To check for an undercharged system, turn the unit on,
allow the compressor to run long enough to establish
working pressures in the system (15 to 20 minutes).
During the cooling cycle you can listen carefully at the exit
of the metering device into the evaporator; an intermittent
hissing and gurgling sound indicates a low refrigerant
charge. Intermittent frosting and thawing of the evaporator
is another indication of a low charge, however, frosting
DQG WKDZLQJFDQ DOVREHFDXVHG E\LQVXI¿FLHQW DLURYHU
the evaporator.
Checks for an undercharged system can be made at
the compressor. If the compressor seems quieter than
normal, it is an indication of a low refrigerant charge.
Overcharged Refrigerant Systems
A check of the amperage drawn by the compressor
motor should show a lower reading. (Check the Unit
6SHFL¿FDWLRQ $IWHU WKH XQLW KDV UXQ  WR  PLQXWHV
check the gauge pressures. Gauges connected to system
with an undercharge will have low head pressures and
substantially low suction pressures.
of the evaporator will not be encountered because the
refrigerant will boil later if at all. Gauges connected to
system will usually have higher head pressure (depending
upon amount of over charge). Suction pressure should be
slightly higher.
Compressor amps will be near normal or higher.
Noncondensables can also cause these symptoms.
7R FRQ¿UP UHPRYH VRPH RI WKH FKDUJH LI FRQGLWLRQV
improve, system may be overcharged. If conditions don’t
improve, Noncondensables are indicated.
Whenever an overcharged system is indicated, always
PDNH VXUH WKDW WKH SUREOHP LV QRW FDXVHG E\ DLU ÀRZ
SUREOHPV,PSURSHUDLUÀRZRYHUWKHHYDSRUDWRUFRLOPD\
indicate some of the same symptoms as an over charged
system.
An overcharge can cause the compressor to fail, since it
would be “slugged” with liquid refrigerant.
The charge for any system is critical. When the compressor
is noisy, suspect an overcharge, when you are sure that
the air quantity over the evaporator coil is correct. Icing
ELECTRIC SHOCK HAZARD
WARNING
Turn off electric power before service or
installation.
Extreme care must be used, if it becomes
necessary to work on equipment with power
applied.
)DLOXUHWRGRVRFRXOGUHVXOWLQVHULRXVLQMXU\RU
death.
Sealed Refrigeration System contains refrigerant
and oil under high pressure.
Proper safety procedures must be followed,
and proper protective clothing must be worn
when working with refrigerants.
Failure to follow these procedures could
UHVXOWLQVHULRXVLQMXU\RUGHDWK
WARNING
HIGH PRESSURE HAZARD
32